Valid 300-610 Exam Dumps Ensure you a HIGH SCORE (2023)
Pass 300-610 Exam with Latest Questions
The Cisco 300-610 exam is designed to assess the students’ understanding of designing the infrastructure of data center by covering the following topics:
- Network Design (35%): This area implies that the potential candidates have knowledge of the Layer 2 connectivity concepts, such as endpoint mobility, availability of redundancy, convergence, and insertion of services. Their understanding of Layer 3 connectivity as well as its elements (IP mobility, graceful restart, and NSF, convergence) and insertion of services is also required. The applicants should be capable of evaluating various data center-related technologies, including vPC, vPC+, VXLAN EVPN, and OTV. Moreover, they need to have a comprehension of various options for routing virtualization and in-band/out-of-band for management.
- Automation Design (20%): The final objective of the test deals with network orchestration along with its automation. Therefore, the examinees must understand DCNM, Inter-sight, NX-API, and Python and should be able to evaluate templates for service profiles, vNIC, vHBA, as well as global and local policies.
- Storage Network Design (20%): As for this section, the test takers should demonstrate their knowledge of the iSCSI deployment plan, including addressing and multipathing schemes and QoS requirements in a data center (FCoE, Iscsi, Fibre Channel, FCIP). Furthermore, this part checks one’s ability to work with Fiber Channel interface, FCoE, and SAN network topology.
- Compute Design (25%): This domain includes the concepts of Ethernet connectivity, such as redundancy, over-subscriptions, and operation modes. Therefore, you must be capable of evaluating various options for storage connection along with the virtualization of network devices in data centers. This includes IOM uplinks, vCon, Ethernet adaptor policies, and policies for the Fiber Channel adapter. The individuals’ knowledge of various hyperconverged infrastructure options, such as cluster mode, desktop virtualization, and HX for the virtual server, is also necessary.
It is important to pay attention to every part of the exam content if you want to excel in the Cisco 300-610 test and earn the passing score, so be ready for a thorough preparation process.
IT practitioners who aim to perfect their data center skills and become an indispensable part of this industry can think of taking-up the Cisco 300-610 exam. Packed with authenticated and refreshed data center management and handling cognizance, this test is here to leverage the understanding of the test-taker at multiple levels.
NEW QUESTION 103
A network design must include a solution to run CLI commands remotely on Cisco Nexus 9000 Series Switches. The customer's security policy requires secure login credentials and an encrypted underlying transport. The command output will be processed using tools that support XML or JSON encoding. Which two components should be included in the design? (Choose two.)
- A. Bash shell
- B. SSH
- C. NX-API
- D. HTTPS
- E. HTTP
Answer: B,D
NEW QUESTION 104
Which two configurations allow for routing traffic between two VDCs? (Choose two.)
- A. Cross-connect the ports between the VDCs.
- B. Create VRF-aware software infrastructure interfaces.
- C. Create interfaces in the VDC that can be accessed by another VDC.
- D. Create a policy map in the default VDC that routes traffic between the VDCs.
- E. Connect the VDCs to an external Layer 3 device.
Answer: D,E
Explanation:
Section: Network Design
NEW QUESTION 105
Which feature must be configured to connect a classical Ethernet network to a data center network so that the data center network appears to be one large switch.
- A. EVPN
- B. UDLD
- C. VPC+
- D. OSPF
Answer: C
Explanation:
A vPC allows links that are physically connected to two different Nexus switches to appear as single portchannel to a server or another switch.
NEW QUESTION 106
Which factor determines the choice of platform designing a Cisco HyperFlex infrastructure to support computer-aided design applications?
- A. processor count
- B. GPU support
- C. network speed
- D. storage capacity
Answer: B
Explanation:
https://www.cisco.com/c/dam/en/us/products/collateral/hyperconverged-infrastructure/hyperflex-hx-series/whitepaper-c11-740243.pdf
https://www.cisco.com/c/dam/en/us/products/collateral/hyperconverged-infrastructure/hyperflex-hx-series/hx-220c-m5-specsheet.pdf
NEW QUESTION 107
Which two configurations are available by using a service profile template in Cisco UCS Manager? (Choose two.)
- A. UUID assignment
- B. target server
- C. ARP entries
- D. number of vHBAs
- E. VXLAN membership
Answer: A,D
Explanation:
Section: Automation Design
Explanation
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/2-2/ b_UCSM_CLI_Configuration_Guide_2_2/b_UCSM_CLI_Configuration_Guide_2_2_chapter_0100000.html
NEW QUESTION 108
Drag the appropriate from the left onto the current UDLD modes of operation on the right.
Answer:
Explanation:

NEW QUESTION 109
Drag and drop the components from the left onto the descriptions on the right that indicate what occurs to Fibre Channel fabric when that component fails.
Answer:
Explanation:
NEW QUESTION 110
Which approach splits a pair of clustered fabric interconnects into two standalone devices?
- A. Run the disable fips-mode command on each fabric interconnect.
- B. Unplug the Layer 1 and Layer 2 interfaces between the devices.
- C. Run the connect local-management command on each fabric interconnect.
- D. Erase the configuration of both fabric interconnects.
Answer: B
Explanation:
Section: Compute Design
Explanation/Reference:
NEW QUESTION 111
A failure occurs on the network between two BFD and OSPF neighbors. Drag and drop the protocol actions from the left into the correct order on the right.
Answer:
Explanation:

NEW QUESTION 112
A network engineer must design a Cisco HyperFlex solution based on these requirements:
* two clusters in the main data center consisting of five HyperFlex nodes
* one edge node for the remote branch
* cluster nodes that use one rack unit of space
Which two devices should be used in the remote branch cluster for this design? (Choose two.)
- A. HX220C
- B. HX240C
- C. UCSB B200
- D. Fabric Interconnect 6300
- E. Gigabit Ethernet Switch
Answer: A,E
NEW QUESTION 113
Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?
- A. FC end-host mode
- B. FC switching mode
- C. NPIV mode
- D. NPV mode
Answer: B
Explanation:
Section: Storage Network Design
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/ Storage-Mgmt/3-1/b_UCSM_GUI_Storage_Management_Guide_3_1/ b_UCSM_GUI_Storage_Management_Guide_3_1_chapter_01110.html
NEW QUESTION 114
A network consultant evaluates the Cisco UCS Fabric Interconnect SAN configuration, which must meet these requirements:
All traffic must pass over the upstream device for switching and domain IDs must be preserved in the fabric.
Each server should be pinned to one designated upstream interface and for the traffic to pass through the pinned port.
Which Fabric Interconnect SAN operational mode meets these requirements?
- A. Fibre Channel
- B. NPIV
- C. end host
- D. switch
Answer: D
NEW QUESTION 115
Drag the appropriate from the left onto the current UDLD modes of operation on the right.
Answer:
Explanation:
NEW QUESTION 116
DRAG DROP
A failure occurs on the network between two BFD and OSPF neighbors. Drag and drop the protocol actions from the left into the correct order on the right.
Select and Place:
Answer:
Explanation:
Section: Network Design
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/ios/12_0s/feature/guide/fs_bfd.html#wp1238898
NEW QUESTION 117
Which orchestration tool provides a graphical interface to manage LAN and SAN fabrics?
- A. Cisco CloudCenter
- B. Cisco Virtual Topology System
- C. Cisco Nexus Fabric Manager
- D. Cisco Data Center Network Manager
Answer: D
Explanation:
Section: Automation Design
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/DCNM_OLH/SAN_Client/fmhelp/ fmc.html#34479
NEW QUESTION 118
DRAG DROP
Drag and drop the components from the left onto the descriptions on the right that indicate what occurs to Fibre Channel fabric when that component fails.
Select and Place:
Answer:
Explanation:
Section: Compute Design
NEW QUESTION 119
Drag and drop the data center technologies from the left onto the correct descriptions on the right. Not all technologies are used.
Answer:
Explanation:
NEW QUESTION 120
Which approach splits a pair of clustered fabric interconnects into two standalone devices?
- A. Run the disable fips-mode command on each fabric interconnect.
- B. Unplug the Layer 1 and Layer 2 interfaces between the devices.
- C. Run the connect local-management command on each fabric interconnect.
- D. Erase the configuration of both fabric interconnects.
Answer: B
Explanation:
Section: Compute Design
NEW QUESTION 121
Drag and drop the technologies from the left onto the correct descriptions on the right.
Answer:
Explanation:
NEW QUESTION 122
An engineer is experiencing performance issues on a Cisco UCS blade server. The B-Series blade server contains four CPUs, most of which are idle. The engineer notices that the CPU is suffering from too many requests sent by the NIC. Additionally, the number of queues appears to be insufficient and only a single CPU is processing the network traffic.
Which policy must be used to alleviate these issues?
- A. LAN connectivity
- B. dynamic vNIC connection
- C. vNIC placement
- D. Ethernet adapter
Answer: B
NEW QUESTION 123
......
300-610 Exam Practice Questions prepared by Cisco Professionals: https://www.actualtorrent.com/300-610-questions-answers.html